MICROTEL CellStat
TM
Microtel CellStat
TM
Operating Manual
28 December 2006
Rev. -
Proprietary Notice:
This document and the subject matter hereto are the
property of MICROTEL, Inc. and shall not be reproduced or copied or used for the
purpose of manufacturing or sale of apparatus, except by written permission of
MICROTEL.
MICROTEL
11725 Sunbelt Court
Suite C
Baton Rouge, LA 70809
225-303-0436
Fax: 225-303-0568
www.microtel-inc.com
Vista de página 0
1 2 3 4 5 6 ... 32 33

Resumo do Conteúdo

Página 1 - MICROTEL

MICROTEL CellStatTM Microtel CellStatTM Operating Manual 28 December 2006 Rev. - Proprietary Notice: This document and the subjec

Página 2

MICROTEL CellStatTM 8 If an incorrect or no access code is entered during a timed access code entry time (10 seconds), the dialer will disconnect a

Página 3 - LIST OF ILLUSTRATIONS

MICROTEL CellStatTM 9CHAPTER 2 - Installation nstallation of the CellStatTM involves several, simple steps. This chapter outlines the physical

Página 4 - INTRODUCTION

MICROTEL CellStatTM 10 Step Two - Telephone Connections (Optional) include the external phone line for call-outs and the optional local telephone

Página 5

MICROTEL CellStatTM 11Step Four - Connect External Input/Output to the Dialer Each Fault input has a corresponding terminal (1 - 4), and there ar

Página 6 - Dialer

MICROTEL CellStatTM 12 Quick Start Procedure This procedure outlines the steps to get the CellStatTM dialer operating in a typical manner with a m

Página 7

MICROTEL CellStatTM 13 Individual Channel Alarm Messages: z Enter **c1 to record an alarm message for a specific I/O channel. (c = 1 to 4 for th

Página 8 - Theory of Operation

MICROTEL CellStatTM 14 CHAPTER 3 - Operation his chapter, divided into Configuration and Operation sections, will explain how to configure the C

Página 9

MICROTEL CellStatTM 15Configuration The configuration commands described in this section modify basic dialer operation and store information about

Página 10 - MICROTEL CellStat

MICROTEL CellStatTM 16 z Answer Delay The number of rings the dialer will see before answering an incoming call on the telephone line. *02 Revi

Página 11 - CHAPTER 2 - Installation

MICROTEL CellStatTM 17Configuring Fault Inputs The CellStatTM features true modularity—Fault input channels operate completely independently of e

Página 12

MICROTEL CellStatTM ii Record of Changes Rev. Date Description of Changes By - 12/28/06 Original Release A

Página 13

MICROTEL CellStatTM 18 NOTE: If C=5, the Power Fault channel, the response is: Example Command: **531 Response: Power fault channel is READY C

Página 14 - Quick Start Procedure

MICROTEL CellStatTM 19Alarm Acknowledgment When CellStatTM calls you, you may wish to respond to the call differently depending on what type of al

Página 15

MICROTEL CellStatTM 20 CHAPTER 4 - Maintenance/Troubleshooting he CellStatTM Dialer is built to require minimal maintenance. Only the system bat

Página 16 - CHAPTER 3 - Operation

MICROTEL CellStatTM 21In addition to minutes being depleted from your dialer’s prepaid cellular account due to the dialer’s usage of the cellular a

Página 17 - Configuration

MICROTEL CellStatTM 22 Troubleshooting Guide Symptom: Unable to place telephone calls (Line LED comes on but no ring at called telephone numb

Página 18

MICROTEL CellStatTM 23cover and turning clockwise to increase loudness, counter-clockwise to decrease. CHAPTER 5 - Advanced Topics his chapter de

Página 19 - Configuring Fault Inputs

MICROTEL CellStatTM 24 Example 2- Program phone number 4 | Call using the built-in cellular communications

Página 20 - Operations

MICROTEL CellStatTM 25APPENDICES APPENDIX A: Technical Specifications A.1 Communications Phone Interface: ACTA ID: US: 7AAAD00BDS65616

Página 21 - Alarm Acknowledgment

MICROTEL CellStatTM 26 AC Power/Battery Charging Indicator Resettable Internal Fuse Optional: Micromax Surge Suppressor Batte

Página 22

MICROTEL CellStatTM 27A.7 Fault Inputs Type: Isolated Dry Contact, Normal Open or Normal Closed, Non-Latched. Sensing frequency: 1 Hz

Página 23 - Spoken Fault/Error Messages

MICROTEL CellStatTM 1TABLE OF CONTENTS INTRODUCTION 2 CHAPTER 1 - DESCRIPTION OF THE CELLSTATTM DIALER 4 CHAPTER 2 - INSTALLATION 9 Quick Start

Página 24 - Troubleshooting Guide

MICROTEL CellStatTM 28 APPENDIX B: Glossary of Dialer Terminology Acknowledge Stops the dialer from placing additional calls concerning an ala

Página 25 - CHAPTER 5 - Advanced Topics

MICROTEL CellStatTM 29APPENDIX C: FCC Requirements This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA

Página 26

MICROTEL CellStatTM 30 APPENDIX D: CellStatTM Command Summary *00 Report system status *01 **01~ Voice system name (10

Página 27 - APPENDICES

MICROTEL CellStatTM 31 Figure 5 Mounting Dimensions

Página 28

MICROTEL CellStatTM 2 INTRODUCTION hank you for choosing the Microtel CellStatTM Dialer to implement your remote alarm monitoring solution. You ha

Página 29

MICROTEL CellStatTM 3 2 11 12 1 10 9 6 7 8 5 3 4 Figure 1: Controls and Indicators

Página 30

MICROTEL CellStatTM 4 CHAPTER 1 - Description of the CellStatTM Dialer he CellStatTM is a small, rugged, and simple, but powerful, device which

Página 31

MICROTEL CellStatTM 5(10) CELLULAR STATUS LED indicates cellular signal strength or call in-progress: BLINK (Rapid) = Cellular initiali

Página 32 - Command Summary

MICROTEL CellStatTM 6 Theory of Operation How Does the Dialer Work? This section provides a simple theory of operation by asking a few questions a

Página 33

MICROTEL CellStatTM 7How does the Dialer Know Who to Call? The dialer has a System Telephone Directory composed of up to 8 user-programmed telephon